ThinkSystem DE6000H - Proveedores de servidores y almacenamiento de China.

Correo electrónico: admin@sell-server.com

Noticias

ThinkSystem DE6000H

ThinkSystem DE6000H CTO base models
Machine Type/Model Base feature Descripción
7Y78CTO2WW BEY7 Lenovo ThinkSystem Storage 2U24 Chassis (with Gen2 controllers and 2x PSUs)
7Y80CTO2WW BQ9W Lenovo ThinkSystem Storage 4U60 Chassis (with Gen2 controllers and 2x PSUs)

The following table lists the preconfigured models wih Gen 2 controllers, available by market.

Mesa 3. Preconfigured models
Modelo Market availability Included HICs
DE6000H – 2U24 – 2x Gen2 16GB controllers
7Y78A00CWW All markets 2x 12Gb SAS 4-port HICs
7Y78A00DWW All markets 2x 32Gb FC 4-port HICs
7Y78A00EWW All markets 2x 10/25Gb iSCSI 4-port HICs
7Y78A00CBR Brasil 2x 12Gb SAS 4-port HICs
7Y78A00DBR Brasil 2x 32Gb FC 4-port HICs
7Y78A00EBR Brasil 2x 10/25Gb iSCSI 4-port HICs
7Y78A00CCN PRC 2x 12Gb SAS 4-port HICs
7Y78A00DCN PRC 2x 32Gb FC 4-port HICs
7Y78A00ECN PRC 2x 10/25Gb iSCSI 4-port HICs
7Y78A00CJP Japón 2x 12Gb SAS 4-port HICs
7Y78A00DJP Japón 2x 32Gb FC 4-port HICs
7Y78A00EJP Japón 2x 10/25Gb iSCSI 4-port HICs
7Y78A00CLA Latin America markets 2x 12Gb SAS 4-port HICs
7Y78A00DLA Latin America markets 2x 32Gb FC 4-port HICs
7Y78A00ELA Latin America markets 2x 10/25Gb iSCSI 4-port HICs
DE6000H – 4U60 – 2x Gen2 16GB controllers
7Y80A00LWW All markets 2x 12Gb SAS 4-port HICs
7Y80A00NWW All markets 2x 10/25Gb iSCSI 4-port HICs
7Y80A00PWW All markets 2x 32Gb FC 4-port HICs
7Y80A00LBR Brasil 2x 12Gb SAS 4-port HICs
7Y80A00MBR Brasil 2x 32Gb FC 4-port HICs
7Y80A00NBR Brasil 2x 10/25Gb iSCSI 4-port HICs
7Y80A00LJP Japón 2x 12Gb SAS 4-port HICs
7Y80A00MJP Japón 2x 32Gb FC 4-port HICs
7Y80A00NJP Japón 2x 10/25Gb iSCSI 4-port HICs
7Y80A00LLA Latin America markets 2x 12Gb SAS 4-port HICs
7Y80A00MLA Latin America markets 2x 32Gb FC 4-port HICs
7Y80A00NLA Latin America markets 2x 10/25Gb iSCSI 4-port HICs
7Y80A00LCN PRC 2x 12Gb SAS 4-port HICs
7Y80A00MCN PRC 2x 32Gb FC 4-port HICs
7Y80A00NCN PRC 2x 10/25Gb iSCSI 4-port HICs

Configuration notes:

  • For preconfigured models, two 16GB DE6000 controllers (feature code BQA2) are included in the model configuration.
  • For CTO models, two DE6000 controllers are required, either 16GB (feature code BQA2) or 64GB (feature code BQA1)

The models of the ThinkSystem DE6000H ship with the following items:

  • One chassis with the following components:
    • Two controllers
    • Two power supplies
    • Two cooling modules (4U60 LFF solo)
    • Two host interface cards
  • Rack Mount Kit
  • 2 m USB Cable (USB Type A to Micro-USB)
  • Quick Installation Guide
  • Electronic Publications Flyer
  • Two power cables:
    • Relationship models listed in this section:
      • 2SFF U24: 1.5 metro, 10A/100-250V, C13 to IEC 320-C14 rack power cables
      • 4U60 LFF: 2.5 metro, 16A/100-240V, C19 to IEC 320-C20 rack power cables
    • CTO models: Customer-configured power cables

Nota: The preconfigured models of the ThinkSystem DE6000H listed in this section ship without optical transceivers, DAC cables, or SAS cables; they should be purchased for the system (ver Controladores para detalles).

Controladores

The ThinkSystem DE6000H controller enclosures ship with two DE6000 controllers, and each controller provides 16 GB o 64 GB de memoria del sistema para un sistema total de 32 GB o 128 ES, respectively. A controller provides interfaces for host connectivity, gestión, and internal drives, and it runs storage management software.

Each controller has one expansion slot for a host interface card (HIC).

The following host interfaces can be added to the ThinkSystem DE6000H controller enclosures with HICs:

  • 8X 12 GB SAS x4 (Mini-SAS HD SFF-8644) puertos (4 ports per HIC) for SAS connectivity.
  • 8X 10/25 GbE SFP28 ports (4 ports per HIC) for 10/25 Conectividad iSCSI Gb (require optical transceivers or DAC cables that should be purchased for the HICs).
  • 8X 8/16/32 Gb FC SFP+ ports (4 ports per HIC) for FC or NVMe/FC connectivity (require optical transceivers that should be purchased for the HICs).
  • 4X 25/40/100 GbE RoCE QSFP28 ports (2 ports per HIC) for NVMe/RoCE connectivity (require optical transceivers or DAC cables that should be purchased for the HIC).

Each DE6000 controller also provide two 12 Gb SAS x4 expansion ports (Mini-SAS HD SFF-8644 connectors) for the attachment of the ThinkSystem DE Series expansion units.

Configuration notes:

  • Both controllers must have the same system memory: 16 GB o 64 ES.
  • Se requieren dos tarjetas de interfaz de host para la selección (uno por controlador).
  • Both controllers must have the same type of the host interface card installed (12 Gb SAS SFF-8644, 32 Gb FC SFP+, 10/25 Gb iSCSI SFP28, o 100 GbE NVMe/RoCE QSFP28), and both cards must have SFP+/SFP28/QSFP28 media of the same type (either optical transceivers or DAC cables, but not both types).
  • NVMe/FC or NVMe/RoCE connectivity requires controllers with 64 GB system memory.

The following table lists the DE6000H controllers and supported connectivity options.

Mesa 6. DE6000H controllers and connectivity options
Número de pieza Código de característica Descripción Maximum quantity per controller enclosure
Controladores
None* B4JN Lenovo ThinkSystem DE6000 Controller 16GB 2
None* B4JP Lenovo ThinkSystem DE6000 Controller 64GB 2
Host interface cards
4C57A14372 B4J9 Lenovo ThinkSystem DE6000 12Gb SAS 4-ports HIC 2
4C57A14371 B4J8 Lenovo ThinkSystem DE6000 10/25Gb iSCSI 4-ports HIC 2
4C57A14370 B4J7 Lenovo ThinkSystem DE6000 32Gb FC 4-ports HIC 2
4C57A14373 B6KW Lenovo ThinkSystem DE6000 100Gb NVMe-RoCE 2-port HIC 2
Transceiver options
4M17A13527 B4B2 Lenovo 10Gb iSCSI/16Gb FC Universal SFP+ Module 4
4M17A13529 B4B4 Lenovo 10/25GbE iSCSI SFP28 Module (for 10/25 Gb iSCSI HIC ports) 8
4M17A13528 B4B3 Lenovo 32Gb FC SFP+ Transceiver (for 32 Gb FC HIC ports) 8
OM4 cables for 16/32 Gb FC and 10/25 Gb iSCSI SW SFP+/SFP28 optical transceivers
4Z57A10845 B2P9 Lenovo 0.5m LC-LC OM4 MMF Cable 12
4Z57A10846 B2PA Lenovo 1m LC-LC OM4 MMF Cable 12
4Z57A10847 B2PB Lenovo 3m LC-LC OM4 MMF Cable 12
4Z57A10848 B2PC Lenovo 5m LC-LC OM4 MMF Cable 12
4Z57A10849 B2PD Lenovo 10m LC-LC OM4 MMF Cable 12
4Z57A10850 B2PE Lenovo 15m LC-LC OM4 MMF Cable 12
4Z57A10851 B2PF Lenovo 25m LC-LC OM4 MMF Cable 12
4Z57A10852 B2PG Lenovo 30m LC-LC OM4 MMF Cable 12
OM3 cables for 16/32 Gb FC and 10/25 Gb iSCSI SW SFP+/SFP28 optical transceivers
00MN499 ASR5 Lenovo 0.5m LC-LC OM3 MMF Cable 12
00MN502 ASR6 Lenovo 1m LC-LC OM3 MMF Cable 12
00MN505 ASR7 Lenovo 3m LC-LC OM3 MMF Cable 12
00MN508 ASR8 Lenovo 5m LC-LC OM3 MMF Cable 12
00MN511 ASR9 Lenovo 10m LC-LC OM3 MMF Cable 12
00MN514 ASRA Lenovo 15m LC-LC OM3 MMF Cable 12
00MN517 ASRB Lenovo 25m LC-LC OM3 MMF Cable 12
00MN520 ASRC Lenovo 30m LC-LC OM3 MMF Cable 12
Active optical cables for 100 Gb NVMe/RoCE QSFP28 HIC ports
7Z57A03546 AV1L Lenovo 3m 100G QSFP28 Active Optical Cable 4
7Z57A03547 AV1M Lenovo 5m 100G QSFP28 Active Optical Cable 4
7Z57A03548 AV1N Lenovo 10m 100G QSFP28 Active Optical Cable 4
7Z57A03549 AV1P Lenovo 15m 100G QSFP28 Active Optical Cable 4
7Z57A03550 AV1Q Lenovo 20m 100G QSFP28 Active Optical Cable 4
DAC cables for iSCSI HIC ports
00D6288 A3RG 0.5m Passive DAC SFP+ Cable 12
90Y9427 A1PH 1m Passive DAC SFP+ Cable 12
00AY764 A51N 1.5m Passive DAC SFP+ Cable 12
00AY765 A51P 2m Passive DAC SFP+ Cable 12
90Y9430 A1PJ 3m Passive DAC SFP+ Cable 12
90Y9433 A1PK 5m Passive DAC SFP+ Cable 12
00D6151 A3RH 7m Passive DAC SFP+ Cable 12
DAC cables for 25 Gb iSCSI SFP28 HIC ports
7Z57A03557 AV1W Lenovo 1m Passive 25G SFP28 DAC Cable 8
7Z57A03558 AV1X Lenovo 3m Passive 25G SFP28 DAC Cable 8
DAC cables for 100 Gb NVMe/RoCE QSFP28 HIC ports
7Z57A03561 AV1Z Lenovo 1m Passive 100G QSFP28 DAC Cable 4
7Z57A03562 AV20 Lenovo 3m Passive 100G QSFP28 DAC Cable 4
7Z57A03563 AV21 Lenovo 5m Passive 100G QSFP28 DAC Cable 4
SAS host connectivity cables: Mini-SAS HD (controller) to Mini-SAS HD (host)
00YL847 AU16 0.5m External MiniSAS HD 8644/MiniSAS HD 8644 Cable 8
00YL848 AU17 1m External MiniSAS HD 8644/MiniSAS HD 8644 Cable 8
00YL849 AU18 2m External MiniSAS HD 8644/MiniSAS HD 8644 Cable 8
00YL850 AU19 3m External MiniSAS HD 8644/MiniSAS HD 8644 Cable 8
1 GbE management ports
00WE123 AVFW 0.75m Green Cat6 Cable 2
00WE127 AVFX 1.0m Green Cat6 Cable 2
00WE131 AVFY 1.25m Green Cat6 Cable 2
00WE135 AVFZ 1.5m Green Cat6 Cable 2
00WE139 AVG0 3m Green Cat6 Cable 2
90Y3718 A1MT 10m Green Cat6 Cable 2
90Y3727 A1MW 25m Green Cat6 Cable 2

* Factory-installed only.

Expansion enclosures

In the base configuration, the ThinkSystem DE6000H supports attachment of up to seven ThinkSystem DE240S 2U24 SFF or ThinkSystem DE120S 2U12 LFF, or up to three ThinkSystem DE600S 4U60 LFF, or a combination of the DE240S 2U24 SFF, DE120S 2U12 LFF, and DE600S 4U60 LFF expansion enclosures for a total of up to 240 drives per system.

With the optional FoD upgrade, the DH6000H supports attachment of up to seven ThinkSystem DE600S 4U60 LFF, or a combination of the DE240S 2U24 SFF, DE120S 2U12 LFF, and DE600S 4U60 LFF expansion enclosures for a total of eight enclosures (one controller enclosure and up to seven expansion enclosures) y hasta 480 drives per system.

Intermezcla de 2U24 SFF, 2Sub-12 LFF, and 4U60 LFF expansion enclosures behind a 2U24 SFF or 4U60 LFF controller enclosure is supported up to the maximum number of enclosures and drives supported per system (depending on whether the optional FoD upgrade is enabled or not). The expansion enclosures can be added to the system non-disruptively.

The following table lists the relationship models of the supported ThinkSystem DE Series expansion enclosures.

Mesa 7. ThinkSystem DE240S, DE120S, and DE600S relationship models
Descripción Número de pieza
Brasil Latin America Porcelana unión Europea Japón Other markets worldwide
Lenovo ThinkSystem DE240S 2U24 SFF Expansion Enclosure 7Y68A004EA 7Y681001JP 7Y68A000WW
Lenovo ThinkSystem DE120S 2U12 LFF Expansion Enclosure 7Y63A003EA 7Y631000JP 7Y63A000WW
Lenovo ThinkSystem DE600S 4U60 LFF Expansion Enclosure Gen2 7Y69A004BR 7Y69A004LA 7Y69A004CN 7Y69A005JP 7Y69A004WW

The following table lists the TopSeller models of the supported ThinkSystem DE Series expansion enclosures.

Mesa 8. ThinkSystem DE240S and DE120S TopSeller models: Brazil and Latin America
Descripción Número de pieza
Latin America Brasil
Lenovo ThinkSystem DE240S 2U24 SFF Expansion Enclosure (TopSeller) 7Y681002LA 7Y681002BR
Lenovo ThinkSystem DE120S 2U12 LFF Expansion Enclosure (TopSeller) 7Y631001LA 7Y631001BR

The following table lists the CTO base models for the ThinkSystem DE Series expansion enclosures.

Mesa 9. ThinkSystem DE240S, DE120S, and DE600S CTO base models
Descripción Machine Type/Model Código de característica
unión Europea Other markets World Wide
Lenovo ThinkSystem Storage 2U24 Chassis (with 2x PSUs) 7Y68CTO1WW BEY7 B38L
Lenovo ThinkSystem Storage 2U12 Chassis (with 2x PSUs) 7Y63CTO1WW BEY6 B38M
Lenovo ThinkSystem Storage 4U60 Chassis (with 2x PSUs) 7Y69CTO2WW BQ9W

Configuration notes:

  • For Relationship and TopSeller models, two I/O expansion modules (feature code B4BS) are included in the model configuration.
  • For CTO models, two I/O expansion modules (feature code B4BS) are selected by default in the configurator, and the selection cannot be changed.

The models of the ThinkSystem DE240S, DE120S, and DE600S ship with the following items:

  • One chassis with the following components:
    • Two I/O modules
    • Two power supplies
    • Two cooling modules (4U60 LFF solo)
  • Four 1 m MiniSAS HD 8644/MiniSAS HD 8644 cables (Models listed in Tables 6 y 7)
  • Rack Mount Kit
  • Quick Installation Guide
  • Electronic Publications Flyer
  • Two power cables:
    • Relationship and TopSeller models listed in this section:
      • 2SFF U24, 2Sub-12 LFF: 1.5 metro, 10A/100-250V, C13 to IEC 320-C14 rack power cables
      • 4U60 LFF: 2.5 metro, 16A/100-240V, C19 to IEC 320-C20 rack power cables
    • CTO models: Customer-configured power cables

Nota: The Relationship and TopSeller models of the ThinkSystem DE240S, DE120S, and DE600S listed in this section ship with four 1 m SAS cables; additional SAS cables that are listed in this section can be purchased for the system, if needed.

Each ThinkSystem DE Series expansion enclosure ships with two SAS I/O expansion modules. Each I/O expansion module provides four external 12 Gb SAS x4 ports (Mini-SAS HD SFF-8644 connectors labelled Port 1-4) that are used for connections to the ThinkSystem DE6000H and for daisy chaining the expansion enclosures between each other.

Two expansion ports on the Controller A are connected to the Ports 1 y 2 on the I/O Module A in the first expansion enclosure in the chain, and the Ports 3 y 4 on the I/O Module A in the first expansion enclosure are connected to the Ports 1 y 2 on the I/O Module A in the adjacent expansion enclosure, and so on.

Two expansion ports on the Controller B are connected to the Ports 1 y 2 on the I/O Module B in the last expansion enclosure in the chain, and the Ports 3 y 4 on the I/O Module B in the expansion enclosure are connected to the Ports 1 y 2 on the I/O Module B in the adjacent expansion enclosure, and so on.

The connectivity topology for the DE Series expansion enclosures is shown in the following figure.

DE Series expansion enclosure connectivity topology
Figure 9. DE Series expansion enclosure connectivity topology

The following table lists ordering information for the supported expansion enclosure connectivity options.

Mesa 10. Expansion unit connectivity options
Descripción Número de pieza Código de característica Quantity per one expansion enclosure
External MiniSAS HD 8644/MiniSAS HD 8644 0.5M Cable 00YL847 AU16 4
External MiniSAS HD 8644/MiniSAS HD 8644 1M Cable 00YL848 AU17 4
External MiniSAS HD 8644/MiniSAS HD 8644 2M Cable 00YL849 AU18 4
External MiniSAS HD 8644/MiniSAS HD 8644 3M Cable 00YL850 AU19 4

Configuration notes:

  • The Relationship and TopSeller models of the ThinkSystem DE240S, DE120S, and DE600S listed in this section ship with four 1 m SAS cables.
  • Four SAS cables are needed per each expansion enclosure (two SAS cables per I/O Module) for connections to the controller enclosure and for daisy chaining of the expansion enclosures.
  • The length of the SAS cables that connect a 2U24 or 2U12 enclosure to an adjacent 4U60 enclosure should be at least 1 meter.

Unidades

The ThinkSystem DE Series 2U24 SFF enclosures support up to 24 SFF hot-swap drives, the 2U12 LFF enclosures support up to 12 LFF hot-swap drives, and the 4U60 LFF enclosures support up to 60 LFF hot-swap drives.

Shipping requirement: 2U12 and 2U24 enclosures can be shipped with all drive bays populated, however the 4U60 enclosures must be shipped with drives removed.

The following table lists supported drive options for the 2U24 SFF controller and expansion enclosures.

Mesa 11. 2U24 SFF drive options
Número de pieza Código de característica DescriptionB4RX Maximum quantity per 2U24 SFF enclosure
2.5-pulgada 12 Gbps SAS hot-swap HDDs
4XB7A14112 B4BY Lenovo ThinkSystem DE Series 1.2TB 10K 2.5HDD 2U24 24
4XB7A14113 B4BZ Lenovo ThinkSystem DE Series 1.8TB 10K 2.5HDD 2U24 24
2.5-pulgada 12 Gbps SAS hot-swap FIPS HDDs (SED HDDs)
4XB7A14114 B4C0 Lenovo ThinkSystem DE Series 1.8TB 10K 2.5HDD FIPS 2U24 24
2.5-pulgada 12 Gbps SAS hot-swap SSDs (1 DWPD)
4XB7A74948 BKUQ Lenovo ThinkSystem DE Series 960GB 1DWD 2.5SSD 2U24 24
4XB7A74951 BKUT Lenovo ThinkSystem DE Series 1.92TB 1DWD 2.5SSD 2U24 24
4XB7A74955 BKUK Lenovo ThinkSystem DE Series 3.84TB 1DWD 2.5SSD 2U24 24
4XB7A14176 B4RY Lenovo ThinkSystem DE Series 7.68TB 1DWD 2.5SSD 2U24 24
4XB7A14110 B4CD Lenovo ThinkSystem DE Series 15.36TB 1DWD 2.5SSD 2U24 24
2.5-pulgada 12 Gbps SAS hot-swap SSDs (3 DWPD)
4XB7A14105 B4BT Lenovo ThinkSystem DE Series 800GB 3DWD 2.5SSD 2U24 24
2.5-pulgada 12 Gbps SAS hot-swap FIPS SSDs (SED SSDs) (3 DWPD)
4XB7A14107 B4BV Lenovo ThinkSystem DE Series 1.6TB 3DWD 2.5SSD FIPS 2U24 24

The following table lists supported drive options for the 2U12 LFF expansion enclosures for the DE6000H.

Mesa 12. Drive options for the 2U12 LFF expansion enclosures
Número de pieza Código de característica Descripción Maximum quantity per 2U12 LFF enclosure
3.5-pulgada 12 Gbps NL SAS hot-swap HDDs
4XB7A14099 B4C3 Lenovo ThinkSystem DE Series 4TB 7.2K 3.5HDD 2U12 12
4XB7A14101 B4C5 Lenovo ThinkSystem DE Series 8TB 7.2K 3.5HDD 2U12 12
4XB7A14102 B4C6 Lenovo ThinkSystem DE Series 10TB 7.2K 3.5HDD 2U12 12
4XB7A14104 B4C8 Lenovo ThinkSystem DE Series 12TB 7.2K 3.5HDD 2U12 12
4XB7A64875 BCVY Lenovo ThinkSystem DE Series 16TB 7.2K 3.5HDD 2U12 12
4XB7A74942 BHDP Lenovo ThinkSystem DE Series 18TB 7.2K 3.5HDD 2U12 12
3.5-pulgada 12 Gbps NL SAS hot-swap FIPS HDDs (SED HDDs)
4XB7A14103 B4C7 Lenovo ThinkSystem DE Series 10TB 7.2K 3.5HDD FIPS 2U12 12
3.5-pulgada 12 Gbps SAS hot-swap SSDs (3 DWPD)
4XB7A14097 B4C1 Lenovo ThinkSystem DE Series 800GB 3DWD 2.5SSD 2U12 12
3.5-pulgada 12 Gbps SAS hot-swap FIPS SSDs (SED SSDs) (3 DWPD) (2.5″ drive in a 3.5tray)
4XB7A14098 B4C2 Lenovo ThinkSystem DE Series 1.6TB 3DWD 2.5SSD FIPS 2U12 12

The following table lists supported drive options for the 4U60 LFF controller and expansion enclosures.

Mesa 13. 4U60 LFF drive options
Número de pieza Código de característica Descripción Maximum quantity per 4U60 LFF enclosure
3.5-pulgada 12 Gbps NL SAS hot-swap HDDs
4XB7A14124 B4GG Lenovo ThinkSystem DE Series 4TB 7.2K 3.5HDD 4U60 60
4XB7A14125 B4GH Lenovo ThinkSystem DE Series 8TB 7.2K 3.5HDD 4U60 60
4XB7A14126 B4GJ Lenovo ThinkSystem DE Series 10TB 7.2K 3.5HDD 4U60 60
4XB7A14128 B4GL Lenovo ThinkSystem DE Series 12TB 7.2K 3.5HDD 4U60 60
4XB7A64876 BCUC Lenovo ThinkSystem DE Series 16TB 7.2K 3.5HDD 4U60 60
4XB7A74943 BHDQ Lenovo ThinkSystem DE Series 18TB 7.2K 3.5HDD 4U60 60
3.5-pulgada 12 Gbps NL SAS hot-swap FIPS HDDs (SED HDDs)
4XB7A14127 B4GK Lenovo ThinkSystem DE Series 10TB 7.2K 3.5HDD FIPS 4U60 60
3.5-pulgada 12 Gbps SAS hot-swap SSDs (1 DWPD) (2.5″ drive in a 3.5tray)
4XB7A86719 BUC8 Lenovo ThinkSystem DE Series 1.92TB 1DWD SAS SSD 4U60 60
3.5-pulgada 12 Gbps SAS hot-swap SSDs (3 DWPD) (2.5″ drive in a 3.5tray)
4XB7A14115 B4G9 Lenovo ThinkSystem DE Series 800GB 3DWD 2.5SSD 4U60 60
4XB7A14116 B4GA Lenovo ThinkSystem DE Series 1.6TB 3DWD 2.5SSD 4U60 60
3.5-pulgada 12 Gbps SAS hot-swap FIPS SSDs (SED SSDs) (3 DWPD) (2.5″ drive in a 3.5tray)
4XB7A14117 B4GB Lenovo ThinkSystem DE Series 1.6TB 3DWD 2.5SSD FIPS 4U60 60

The following table lists supported drive pack options for the 4U60 LFF controller and expansion enclosures.

Mesa 14. 4U60 LFF drive pack options
Número de pieza Código de característica Descripción Maximum quantity per 4U60 LFF enclosure
3.5-pulgada 12 Gbps NL SAS hot-swap HDD packs
4XB7A14164 B4HY Lenovo ThinkSystem DE6000H 80TB HDD Pack (20x 4TB HDDs) 3
4XB7A14166 B4HZ Lenovo ThinkSystem DE6000H 160TB HDD Pack (20x 8TB HDDs) 3
4XB7A14168 B4J0 Lenovo ThinkSystem DE6000H 200TB HDD Pack (20x 10TB HDDs) 3
4XB7A14172 B4J2 Lenovo ThinkSystem DE6000H 240TB HDD Pack (20x 12TB HDDs) 3
4XB7A64878 BCUE Lenovo ThinkSystem DE6000H 320TB HDD Pack (20x 16TB HDDs) 3
4XB7A74945 BHDS Lenovo ThinkSystem DE6000H 360TB HDD Pack (20x 18TB HDDs) 3
3.5-pulgada 12 Gbps NL SAS hot-swap FIPS HDD packs (SED HDD packs)
4XB7A14170 B4J1 Lenovo ThinkSystem DE6000H 200TB HDD FIPS Pack (20x 10TB FIPS HDDs) 3
3.5-pulgada 12 Gbps SAS hot-swap SSD packs (1 DWPD) (2.5″ drive in a 3.5tray)
4XB7A86720* BUC9 Lenovo ThinkSystem DE4000H 38.4TB Pack (20x 1.92TB SAS SSDs) 3
4XB7A86721 BUCA Lenovo ThinkSystem DE6000H 38.4TB Pack (20x 1.92TB SAS SSDs) 3
3.5-pulgada 12 Gbps SAS hot-swap SSD packs (3 DWPD) (2.5″ drive in a 3.5tray)
4XB7A14162 B4HX Lenovo ThinkSystem DE6000H 32TB SSD Pack (20x 1.6TB SSDs) 3

*Supported in the DE600S 4U60 LFF Expansion Enclosure (7Y69) solo.

Configuration notes:

  • For hybrid (HDDs and SSDs) and all flash (SSDs only) storage configurations, a single ThinkSystem DE6000H storage system can support a maximum of 120 SSD.
  • A minimum of 20 drives is required for each 4U60 LFF enclosure (the front row of each drawer must be populated with four drives).
  • Intermix of FIPS drives and non-FIPS drives is supported within the system.
  • FIPS drives are not available in the following countries:
    • Bielorrusia
    • Kazajstán
    • People’s Republic of China
    • Rusia

Software

The following functions are included with every ThinkSystem DE6000H:

  • Niveles de RAID 0, 1, 3, 5, 6, y 10: Provide the flexibility to choose the level of performance and data protection required.
  • Grupos de discos dinámicos (DDP) technology: Helps improve performance and availability with significantly faster rebuild time and reduced exposure to multiple drive failures by allowing data and built-in spare capacity to be distributed across all physical drives in the storage pool.
  • All Flash Array (AFA) capability: Meets the demand for higher speed storage and provide higher IOPS and bandwidth with lower power usage and total cost of ownership than hybrid or HDD-based solutions.
  • SSD Read Cache: Helps accelerate performance of read-centric workloads.
  • Thin provisioning: Optimizes efficiency of Dynamic Disk Pools by allocating storage space based on the minimum space required by each application at any given time, so that applications consume only the space they are actually using, not the total space that has been allocated to them, which allows customers to purchase storage they need today and add more as application requirements grow.
  • Instantáneas: Enables creation of copies of data for backup, parallel processing, testing, and development, and have the copies available almost immediately (hasta 1024 snapshot targets per system).
  • Cifrado: Provides encryption for data at rest for enhanced data security with the optional FIPS 140-2 Level 2 drives and embedded key management (AES-256) or an external key management server.
  • Automatic load balancing: Provides automated I/O workload balancing of I/O traffic from the hosts across both controllers.
  • Data assurance: Ensures industry-standard T10-PI end-to-end data integrity in the storage system (from the host ports to the drives).
  • Dynamic volume and capacity expansion: Allows the capacity of a volume to be expanded by adding new physical drives or making use of unused space on existing drives.

The ThinkSystem DE6000H capabilities can be expanded with optional licensed functions. Optional licensed functions include:

  • Snapshots upgrade: Increase the supported number of snapshot targets to 2048.
  • Scalability to 480 unidades: Increases the number of supported 4U60 LFF expansion enclosures to 7 for up to 480 LFF drives per system.
  • Synchronous mirroring: Provides storage system-based online, real-time data replication between the storage systems containing primary (local) and secondary (remote) volumes by using synchronous data transfers over Fibre Channel communication links (both storage systems must have licenses for synchronous mirroring).
  • Asynchronous mirroring: Provides storage system-based data replication between the storage systems containing primary (local) and secondary (remote) volumes by using asynchronous data transfers over iSCSI or Fibre Channel communication links at set intervals (both storage systems must have licenses for asynchronous mirroring).

Nota: The synchronous and asynchronous mirroring features of the ThinkSystem DE6000H interoperate with other ThinkSystem DE Series storage arrays.

The following table lists the Feature on Demand (FoD) upgrades for the ThinkSystem DE6000H to enable optional software features. Each optional DE6000H function is licensed on a per-system basis and covers both controller enclosure and all attached expansion enclosures.

Mesa 15. Funciones de software opcionales
Descripción Número de pieza Código de característica
Lenovo ThinkSystem DE6000H Snapshots Upgrade 2048 4ZN7A14704 B4JA
Lenovo ThinkSystem DE6000H Max Drive Count Increase to 480 4ZN7A14710 B597
Lenovo ThinkSystem DE6000H Synchronous Mirroring 4ZN7A14706 B4JB
Lenovo ThinkSystem DE6000H Asynchronous Mirroring 4ZN7A14707 B4JC

Software maintenance is included in the ThinkSystem DE6000H base warranty and optional warranty extensions, which provides 3-year software support with the option to extend it up to 5 years in 1-year or 2-year increments (see Warranty and support for details).

Gestión

The DE6000H supports the following management interfaces:

  • ThinkSystem System Manager, a web-based interface via HTTPS for single-system management, that runs on the storage system itself and requires only a supported browser, so there is no need for a separate console or plug-in. For more information, see the System Manager Online Help.
  • ThinkSystem SAN Manager, a host-installed GUI-based application, for centralized management of multiple storage systems. For more information, see the SAN Manager Online Help.
  • ThinkSystem DE Series Storage Plugin for vCenter. For more information, see the DE Series vCenter Plugin Online Help.
  • Command line interface (CLI) via SSH or through serial console. For more information, see the CLI Online Help.
  • Syslog, SNMP, and e-mail notifications.
  • Optional Lenovo XClarity Administrator support for discovery, inventory, and monitoring.

Power supplies and cables

The ThinkSystem DE Series 2U24 SFF and 2U12 LFF enclosures ship with two redundant hot-swap 913W (100-240V) Fuentes de alimentación de CA de platino, each with an IEC 320-C14 connector. The Relationship models of the ThinkSystem DE6000H 2U24 SFF, DE240S 2U24 SFF, and DE120S 2U12 LFF enclosures listed in Controller enclosures and Expansion enclosures ship with two 1.5 metro, 10A/100-250V, C13 to IEC 320-C14 rack power cables.

The ThinkSystem DE Series 4U60 LFF enclosures ship with two redundant hot-swap 2325 W (200 – 240 V) Fuentes de alimentación de CA de platino, each with an IEC 320-C20 connector. The Relationship models of the ThinkSystem DE6000H 4U60 LFF and DE600S 4U60 LFF enclosures listed in Controller enclosures and Expansion enclosures ship with two 2.5 metro, 16A/100-240V, C19 to IEC 320-C20 rack power cables.

The CTO models require the selection of two power cables.

The following table lists the rack power cable and line cord options that can be ordered for the DE Series 2U24 SFF enclosures (two power cords per enclosure).

Mesa 16. Power cables for DE Series 2U24 SFF and 2U12 LFF enclosures
Descripción Número de pieza Código de característica
Rack power cables
1.0metro, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 00Y3043 A4VP
1.0metro, 13A/100-250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08367 B0N5
1.5metro, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 39Y7937 6201
1.5metro, 13A/100-250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08368 B0N6
2.0metro, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08365 B0N4
2.0metro, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08369 6570
2.8metro, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08366 6311
2.8metro, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08370 6400
2.8metro, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable 39Y7938 6204
4.3metro, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 39Y7932 6263
4.3metro, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08371 6583
Line cords
Argentina 2.8m, 10A/250V, C13 to IRAM 2073 Line Cord 39Y7930 6222
Argentina 4.3m, 10A/250V, C13 to IRAM 2073 Line Cord 81Y2384 6492
Australia/New Zealand 2.8m, 10A/250V, C13 to AS/NZS 3112 Line Cord 39Y7924 6211
Australia/New Zealand 4.3m, 10A/250V, C13 to AS/NZS 3112 Line Cord 81Y2383 6574
Brazil 2.8m, 10A/250V, C13 to NBR 14136 Line Cord 69Y1988 6532
Brazil 4.3m, 10A/250V, C13 to NBR14136 Line Cord 81Y2387 6404
China 2.8m, 10A/250V, C13 to GB 2099.1 Line Cord 39Y7928 6210
China 4.3m, 10A/250V, C13 to GB 2099.1 Line Cord 81Y2378 6580
Denmark 2.8m, 10A/250V, C13 to DK2-5a Line Cord 39Y7918 6213
Denmark 4.3m, 10A/250V, C13 to DK2-5a Line Cord 81Y2382 6575
Europe 2.8m, 10A/250V, C13 to CEE7-VII Line Cord 39Y7917 6212
Europe 4.3m, 10A/250V, C13 to CEE7-VII Line Cord 81Y2376 6572
India 2.8m, 10A/250V, C13 to IS 6538 Line Cord 39Y7927 6269
India 4.3m, 10A/250V, C13 to IS 6538 Line Cord 81Y2386 6567
Israel 2.8m, 10A/250V, C13 to SI 32 Line Cord 39Y7920 6218
Israel 4.3m, 10A/250V, C13 to SI 32 Line Cord 81Y2381 6579
Italy 2.8m, 10A/250V, C13 to CEI 23-16 Line Cord 39Y7921 6217
Italy 4.3m, 10A/250V, C13 to CEI 23-16 Line Cord 81Y2380 6493
Japan 2.8m, 12A/125V, C13 to JIS C-8303 Line cord 46M2593 A1RE
Japan 2.8m, 12A/250V, C13 to JIS C-8303 Line Cord 4L67A08357 6533
Japan 4.3m, 12A/125V, C13 to JIS C-8303 Line Cord 39Y7926 6335
Japan 4.3m, 12A/250V, C13 to JIS C-8303 Line Cord 4L67A08362 6495
Korea 2.8m, 12A/250V, C13 to KS C8305 Line Cord 39Y7925 6219
Korea 4.3m, 12A/250V, C13 to KS C8305 Line Cord 81Y2385 6494
South Africa 2.8m, 10A/250V, C13 to SABS 164 Line Cord 39Y7922 6214
South Africa 4.3m, 10A/250V, C13 to SABS 164 Line Cord 81Y2379 6576
Switzerland 2.8m, 10A/250V, C13 to SEV 1011-S24507 Line Cord 39Y7919 6216
Switzerland 4.3m, 10A/250V, C13 to SEV 1011-S24507 Line Cord 81Y2390 6578
Taiwan 2.8m, 10A/125V, C13 to CNS 10917-3 Line Cord 23R7158 6386
Taiwan 2.8m, 10A/250V, C13 to CNS 10917-3 Line Cord 81Y2375 6317
Taiwan 2.8m, 15A/125V, C13 to CNS 10917-3 Line Cord 81Y2374 6402
Taiwan 4.3m, 10A/125V, C13 to CNS 10917-3 Line Cord 4L67A08363 AX8B
Taiwan 4.3m, 10A/250V, C13 to CNS 10917-3 Line Cord 81Y2389 6531
Taiwan 4.3m, 15A/125V, C13 to CNS 10917-3 Line Cord 81Y2388 6530
United Kingdom 2.8m, 10A/250V, C13 to BS 1363/A Line Cord 39Y7923 6215
United Kingdom 4.3m, 10A/250V, C13 to BS 1363/A Line Cord 81Y2377 6577
United States 2.8m, 10A/125V, C13 to NEMA 5-15P Line Cord 90Y3016 6313
United States 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord 46M2592 A1RF
United States 2.8m, 13A/125V, C13 to NEMA 5-15P Line Cord 00WH545 6401
United States 4.3m, 10A/125V, C13 to NEMA 5-15P Line Cord 4L67A08359 6370
United States 4.3m, 10A/250V, C13 to NEMA 6-15P Line Cord 4L67A08361 6373
United States 4.3m, 13A/125V, C13 to NEMA 5-15P Line Cord 4L67A08360 AX8A

The following table lists the rack power cable and line cord options that can be ordered for the DE Series 4U60 LFF enclosures (two power cords per enclosure).

Mesa 17. Power cables for DE Series 4U60 enclosures
Descripción Número de pieza Código de característica
Rack power cables
2.0metro, 16A/100-250V, C19 to IEC 320-C20 Rack Power Cable None* B4L2
2.5metro, 16A/100-250V, C19 to IEC 320-C20 Rack Power Cable 39Y7916 6252
Line cords
Argentina 4.3m, 16A/250V, C19 to IRAM 2073 Line Cord 40K9777 6276
Australia/New Zealand 4.3m, 15A/250V, C19 to AS/NZS 3112 Line Cord 40K9773 6284
Brazil 4.3m, 16A/250V, C19 to NBR 14136 Line Cord 40K9775 6277
China 4.3m, 16A/250V, C19 to GB2099.1 Line Cord 40K9774 6288
Denmark/Switzerland 4.3m, 16A/250V, C19 to IEC 309 P+N+G Line Cord 40K9769 6283
Europe 4.3m, 16A/250V, C19 to CEE7-VII Line Cord 40K9766 6279
India 4.3m, 16A/250V, C19 to IS6538 Line Cord 40K9776 6285
Israel 4.3m, 16A/250V, C19 to SI 32 Line Cord 40K9771 6282
Italy 4.3m, 16A/250V, C19 to CEI 23-16 Line Cord 40K9768 6281
Japan 4.3m, 15A/200V, C19 to JIS C-8303 Line Cord 41Y9233 6291
Korea 4.3m, 15A/250V, C19 to KSC 8305 Line Cord 41Y9231 6289
South Africa 4.3m, 16A/250V, C19 to SABS 164 Line Cord 40K9770 6280
Switzerland 4.3m, 16A/250V, C19 to SEV 1011 Line Cord 81Y2391 6549
Taiwan 4.3m, 16A/250V, C19 to CNS 10917-3 Line Cord 41Y9230 6287
United Kingdom 4.3m, 13A/250V, C19 to BS 1363/A Line Cord 40K9767 6278
United States 4.3m, 15A/250V, C19 to NEMA 6-15P Line Cord 00D7197 A1NV
United States 4.3m, 18A/250V, C19 to NEMA L6-20P Line Cord 40K9772 6275

* Solo director de tecnología.

Rack installation

The individually shipped ThinkSystem DE Series 2U12 enclosures come with the ThinkSystem Storage Rack Mount Kit 2U12, and the individually shipped ThinkSystem DE Series 2U24 and 4U60 enclosures come with the ThinkSystem Storage Rack Mount Kit 2U24/4U60. These rack mount kits are listed in the following table.

Mesa 18. 4-post rack mount kits
Descripción Código de característica Quantity
Lenovo ThinkSystem Storage Rack Mount Kit 2U12 B38X 1
Lenovo ThinkSystem Storage Rack Mount Kit 2U24/4U60 B38Y 1

When the ThinkSystem DE Series enclosures are factory-integrated and shipped installed in a rack cabinet, the rack mount kits that support Ship-in-Rack (SIR) capabilities are derived by the configurator. The SIR-capable rack mount kits are listed in the following table.

Mesa 19. 4-post SIR rack mount kits
Descripción Código de característica Quantity
Lenovo ThinkSystem Storage Rack Mount Kit 2U12 B38X 1
Lenovo ThinkSystem Storage SIR Rack Mount Kit (for 2U24 enclosures) B6TH 1
DM/DE 4U Adjustable Rail Kit (SIR) B742 1

The following table summarizes the rack mount kit features and specifications.

Mesa 20. Rack mount kit features and specifications summary
Atributo Screw-in fixed rail with adjustable depth
2U12 2U24/4U60 2U24 SIR 4U SIR
Código de característica B38X B38Y B6TH B742
Enclosure support DE120S DE6000H 2U
DE6000H 4U‡
DE240S
DE600S‡
DE6000H 2U
DE240S
DE6000H 4U‡
DE600S‡
Rail type Fixed (static) with adjustable depth Fixed (static) with adjustable depth Fixed (static) with adjustable depth Fixed (static) with adjustable depth
Tool-less installation No No No No
In-rack maintenance Yes* Yes* Yes* Yes*
Ship-in-rack (SIR) support No
1U PDU support
0U PDU support Limited** Limited** Limited** Limited**
Rack type IBM or Lenovo 4-post, IEC standard-compliant IBM or Lenovo 4-post, IEC standard-compliant IBM or Lenovo 4-post, IEC standard-compliant IBM or Lenovo 4-post, IEC standard-compliant
Mounting holes Square or round Square or round Square or round Square or round
Mounting flange thickness 2 milímetro (0.08 en.)
3.3 milímetro (0.13 en.)
2 milímetro (0.08 en.)
3.3 milímetro (0.13 en.)
2 milímetro (0.08 en.)
3.3 milímetro (0.13 en.)
2 milímetro (0.08 en.)
3.3 milímetro (0.13 en.)
Distance between front and rear mounting flanges^ 605 milímetro (23.8 en.)
812.8 milímetro (32 en.)
605 milímetro (23.8 en.)
812.8 milímetro (32 en.)
605 milímetro (23.8 en.)
812.8 milímetro (32 en.)
605 milímetro (23.8 en.)
812.8 milímetro (32 en.)

‡ The rack cabinet must be at least 1100 milímetro (43.31 en.) deep for 4U60 enclosures.
* The majority of the enclosure components can be serviced from the front or rear of the enclosure, which does not require the removal of the enclosure from the rack cabinet.
** If a 0U PDU is used, the rack cabinet must be at least 1000 milímetro (39.37 en.) deep for 2U12 and 2U24 enclosures, or at least 1200 milímetro (47.24 en.) deep for 4U60 enclosures.
^ Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail.

Physical specifications

The ThinkSystem DE Series 2U24 SFF enclosures have the following dimensions:

  • Altura: 85 milímetro (3.4 en.)
  • Ancho: 449 milímetro (17.7 en.)
  • Profundidad: 553 milímetro (21.8 en.)

The ThinkSystem DE Series 2U12 LFF enclosures have the following dimensions:

  • Altura: 85 milímetro (3.4 en.)
  • Ancho: 447 milímetro (17.6 en.)
  • Profundidad: 483 milímetro (19.0 en.)

The ThinkSystem DE Series 4U60 LFF enclosures have the following dimensions:

  • Altura: 174 milímetro (6.9 en.)
  • Ancho: 449 milímetro (17.7 en.)
  • Profundidad: 922 milímetro (36.3 en.)

Weights of enclosures (completamente configurado):

  • Gabinete del controlador DE6000H 2U24 SFF (7Y78): 25.07 kg (55.3 libras)
  • Gabinete del controlador DE6000H 4U60 LFF (7Y80): 108.49 kg (239.2 libras)
  • Gabinete de expansión DE240S 2U24 SFF (7Y68): 27.44 kg (60.5 libras)
  • Gabinete de expansión DE120S 2U12 LFF (7Y63): 27.12 kg (59.8 libras)
  • Gabinete de expansión DE600S 4U60 LFF (7Y69): 112.2 kg (247.4 libras)

 

Operating environment

The ThinkSystem DE Series 2U24 SFF and 4U60 LFF enclosures are supported in the following environment:

  • Air temperature:
    • Operating:
      • DE6000H and DE240S 2U24 SFF: 5 °C – 45 °C (41 °F – 113 °F)
      • DE6000H and DE600S 4U60 LFF: 10 °C – 40 °C (50 °F – 104 °F)
      • DE120S 2U12 LFF: 10 °C – 40 °C (50 °F – 104 °F)
    • Non-operating: -10 °C – +50 °C (14 °F – 122 °F)
    • Maximum altitude: 3050 metro (10,000 ft)
  • Relative humidity:
    • Operating: 8% – 90% (non-condensing)
    • Non-operating: 10% – 90% (non-condensing)
  • Electrical power:
    • 100 to 127 VCA (nominal); 50 Hz / 60 Hz (except 4U60 LFF enclosures)
    • 200 to 240 VCA (nominal); 50 Hz / 60 Hz
  • Acoustical noise emission:
    • DE6000H 2U24 SFF, DE6000H and DE600S 4U60 SFF: 7.2 bels
    • DE240S 2U24 SFF and DE120S 2U12 LFF: 6.6 bels

The following table lists the maximum enclosure power load, inlet current, and heat output based on the source voltage.

Mesa 21. Enclosure power load, inlet current, and heat output
Recinto Source voltage
(nominal)
Máximo
power load
Current
per inlet
Heat output
DE6000H 2U24 SFF 100 – 127 VCA 814 W 8.57 A 2778 BTU/hour
200 – 240 VCA 705 W 3.72 A 2406 BTU/hour
DE6000H 4U60 LFF 200 – 240 VCA 1638 W 8.63 A 5589 BTU/hour
DE240S 2U24 SFF 100 – 127 VCA 389 W 4.1 A 1328 BTU/hour
200 – 240 VCA 382 W 2.02 A 1304 BTU/hour
DE120S 2U12 LFF 100 – 127 VCA 306 W 3.3 A 1045 BTU/hour
200 – 240 VCA 300 W 1.58 A 1024 BTU/hour
DE600S 4U60 LFF 200 – 240 VCA 1446 W 7.62 A 4934 BTU/hour

Próximo:

Deja una respuesta

WhatsApp whatsapp/wechat:+86 13811827366

Correo electrónico admin@sell-server.com

Dejar un mensaje