Fattore di forma |
- Lenovo Storage V3700 V2 Control Enclosure: 2Montaggio su rack a U
- Lenovo Storage V3700 V2 XP Control Enclosure: 2Montaggio su rack a U
- Lenovo Storage V3700 V2 Expansion Enclosure: 2Montaggio su rack a U
|
Controller
configuration |
Dual controller (known as node canister) configuration. |
Livelli RAID |
RAID 0, 1, 5, 6, E 10; Distributed RAID 5 E 6. |
Controller cache |
16 GB per sistema (8 GB per node canister). V3700 XP is upgradeable to 32 GB (16 GB per node canister). Cache mirroring between the node canisters. Protezione della cache supportata da flash (includes battery). |
Drive bay |
Fino a 264 SFF drive bays per storage system:
- 24 SFF drive bays in the control enclosure
- 24 SFF drive bays in the expansion enclosure; fino a 10 contenitori di espansione
Fino a 132 LFF drive bays per storage system:
- 12 LFF drive bays in the control enclosure
- 12 LFF drive bays in the expansion enclosures; fino a 10 contenitori di espansione
Intermix of SFF and LFF enclosures is supported. |
Tecnologia di guida |
SAS and NL SAS HDDs and SAS SSDs. Intermix of HDDs and SSDs is supported. |
Drive connectivity |
Dual-ported 12 Gb SAS drive attachment infrastructure.
Controller unit with two node canisters (ports per one node canister):
- 24X 12 Gb SAS internal drive ports (SFF enclosure)
- 12X 12 Gb SAS internal drive ports (LFF enclosure)
- 1X 12 Gb SAS x4 (Mini SAS HD SFF-8644) expansion port for the attachment of the expansion enclosures
Expansion unit with two expansion canisters (ports per one expansion canister):
- 24X 12 Gb SAS internal drive ports (SFF enclosure)
- 12X 12 Gb SAS internal drive ports (LFF enclosure)
- 2X 12 Gb SAS x4 (Mini SAS HD SFF-8644) expansion ports for the daisy chained attachment of the expansion enclosures
|
Unità |
SFF drives:
- 300 GB, 600 GB, E 900 GB 15K rpm SAS HDDs
- 900 GB, 1.2 tubercolosi, 1.8 tubercolosi, E 2.4 TB 10K rpm SAS HDDs
- 2 TB 7.2K rpm NL SAS HDDs
- 400 GB, 800 GB, 1.6 tubercolosi, E 3.2 TB SAS SSDs
- 1.92 tubercolosi, 3.84 tubercolosi, 7.68 tubercolosi, E 15.36 TB read-optimized SAS SSDs
Azionamenti LFF:
- 300 GB, 600 GB, E 900 GB 15K rpm SAS HDDs
- 900 GB, 1.2 tubercolosi, 1.8 tubercolosi, E 2.4 TB 10K rpm SAS HDDs
- 4 tubercolosi, 6 tubercolosi, 8 tubercolosi, 10 tubercolosi, E 12 TB 7.2K rpm NL SAS HDDs
|
Capacità di memoria |
Fino a 4.055 PB (264X 15.36 TB SAS SSDs) |
Connettività host |
Standard ports (per control enclosure with two node canisters):
- 4X 1 Gb iSCSI host ports (UTP, RJ-45) (2 ports per node canister)
- 4X 12 Porte host SAS da Gb (Mini-SAS HD, SFF-8644) (2 ports per node canister; V3700 V2 XP only)
Optional additional ports on host interface cards (per control enclosure with two node canisters):
- 8X 12 Porte host SAS da Gb (Mini-SAS HD, SFF-8644) (4 ports per node canister)
- 8X 1 Gb iSCSI host ports (UTP, RJ-45) (4 ports per node canister)
- 8X 10 Gb iSCSI or FCoE SFP+ host ports (SW fiber, LC) (4 ports per node canister)
- 8X 16 Porte host FC SFP+ da Gb (SW or LW fiber, LC) (4 ports per node canister)
- 4X 25 GB iSCSI (RoCE) SFP28 host ports (SW fiber, LC) (2 ports per node canister)
- 4X 25 GB iSCSI (iWARP) SFP28 host ports (SW fiber, LC) (2 ports per node canister)
|
Host operating systems^ |
Server Microsoft Windows 2012, 2012 R2, E 2016; RedHat EnterpriseLinux (REL) 6 E 7; SUSELinux Enterprise Server (SLES) 11 E 12; VMware vSphere 5.1, 5.5, 6.0, E 6.5. |
Funzionalità standard del software |
Virtualization of internal storage, Thin Provisioning, Data reduction pools, One-way Data Migration, FlashCopy snapshots (fino a 64 bersagli), and Embedded GUI. |
Funzionalità software opzionali |
FlashCopy snapshots upgrade (fino a 2048 bersagli), Easy Tier, Crittografia (V3700 XP only), and Remote Mirroring. |
Performance
(V3700 V2 / V3700 V2 XP)* |
- Fino a 168 000 / 390 000 cache read IOPS
- Fino a 65 000 / 114 000 disk read IOPS
- Fino a 17 000 / 29 000 disk write IOPS
- Fino a 32 000 / 54 000 disk mixed (70% read/30% write) IOPS
- Fino a 4.2 / 6.3 GBps sequential disk read throughput
- Fino a 1.1 / 1.7 GBps sequential disk write throughput
|
Valori massimi di configurazione** |
Per system:
- Maximum number of storage pools: 1024
- Numero massimo di volumi logici: 2048
- Dimensione massima del volume logico: 256 tubercolosi
- Maximum number of drives in a RAID array: 16
- Maximum number of RAID arrays: 128
- Maximum number of drives in a distributed RAID array: 128 (including up to 4 spares)
- Maximum number of distributed RAID arrays: 10
- Maximum hot spare drives: No limit
- Maximum number of host ports: 2048
- Numero massimo di host: 256
- Maximum number of host ports per one host: 32
- Numero massimo di snapshot: 2048 (richiede una licenza opzionale)
- Maximum number of remote mirroring relationships: 2048 (richiede una licenza opzionale)
|
Raffreddamento |
Redundant cooling with the fan modules that are built into power supplies. |
Alimentazione elettrica |
Due hot-swap ridondanti 800 W AC power supplies. |
Parti sostituibili a caldo |
Node canisters, expansion canisters, SFP+/SFP28 transceivers, azionamenti, power supplies with fans. |
Interfacce di gestione |
2X 1 GbE ports (UTP, RJ-45) in a primary/redundant configuration.
Web-based GUI; CLI SSH; SMI-S; SNMP and email notifications. |
Caratteristiche di sicurezza |
Livello socket sicuro (SSL), Guscio sicuro (SSH), sicurezza a livello di utente, Autenticazione LDAP |
Warranty |
Three-year customer-replaceable unit and onsite warranty with 9×5 next business day terms. Optional warranty service upgrades are available through Lenovo: 24×7 coverage, 2-hour or 4-hour response time, 6-hour or 24-hour committed repair, 1-year or 2-year warranty extensions, YourDrive I tuoi dati. |
Dimensioni |
Altezza: 87 mm (3.4 In.); width: 483 mm (19.0 In.); depth: 556 mm (21.9 In.) |
Peso |
- Control enclosure (completamente configurato): 26 kg (57.3 libbre)
- Expansion enclosure (completamente configurato): 26.7 kg (58.9 libbre)
|