Machine Type/Model | Base feature | Description |
---|---|---|
7Y78CTO2WW | BEY7 | Lenovo ThinkSystem Storage 2U24 Chassis (with Gen2 controllers and 2x PSUs) |
7Y80CTO2WW | BQ9W | Lenovo ThinkSystem Storage 4U60 Chassis (with Gen2 controllers and 2x PSUs) |
The following table lists the preconfigured models wih Gen 2 controllers, available by market.
Model | Market availability | Included HICs |
---|---|---|
DE6000H – 2U24 – 2x Gen2 16GB controllers | ||
7Y78A00CWW | All markets | 2x 12Gb SAS 4-port HICs |
7Y78A00DWW | All markets | 2x 32Gb FC 4-port HICs |
7Y78A00EWW | All markets | 2x 10/25Gb iSCSI 4-port HICs |
7Y78A00CBR | Brazil | 2x 12Gb SAS 4-port HICs |
7Y78A00DBR | Brazil | 2x 32Gb FC 4-port HICs |
7Y78A00EBR | Brazil | 2x 10/25Gb iSCSI 4-port HICs |
7Y78A00CCN | PRC | 2x 12Gb SAS 4-port HICs |
7Y78A00DCN | PRC | 2x 32Gb FC 4-port HICs |
7Y78A00ECN | PRC | 2x 10/25Gb iSCSI 4-port HICs |
7Y78A00CJP | Japan | 2x 12Gb SAS 4-port HICs |
7Y78A00DJP | Japan | 2x 32Gb FC 4-port HICs |
7Y78A00EJP | Japan | 2x 10/25Gb iSCSI 4-port HICs |
7Y78A00CLA | Latin America markets | 2x 12Gb SAS 4-port HICs |
7Y78A00DLA | Latin America markets | 2x 32Gb FC 4-port HICs |
7Y78A00ELA | Latin America markets | 2x 10/25Gb iSCSI 4-port HICs |
DE6000H – 4U60 – 2x Gen2 16GB controllers | ||
7Y80A00LWW | All markets | 2x 12Gb SAS 4-port HICs |
7Y80A00NWW | All markets | 2x 10/25Gb iSCSI 4-port HICs |
7Y80A00PWW | All markets | 2x 32Gb FC 4-port HICs |
7Y80A00LBR | Brazil | 2x 12Gb SAS 4-port HICs |
7Y80A00MBR | Brazil | 2x 32Gb FC 4-port HICs |
7Y80A00NBR | Brazil | 2x 10/25Gb iSCSI 4-port HICs |
7Y80A00LJP | Japan | 2x 12Gb SAS 4-port HICs |
7Y80A00MJP | Japan | 2x 32Gb FC 4-port HICs |
7Y80A00NJP | Japan | 2x 10/25Gb iSCSI 4-port HICs |
7Y80A00LLA | Latin America markets | 2x 12Gb SAS 4-port HICs |
7Y80A00MLA | Latin America markets | 2x 32Gb FC 4-port HICs |
7Y80A00NLA | Latin America markets | 2x 10/25Gb iSCSI 4-port HICs |
7Y80A00LCN | PRC | 2x 12Gb SAS 4-port HICs |
7Y80A00MCN | PRC | 2x 32Gb FC 4-port HICs |
7Y80A00NCN | PRC | 2x 10/25Gb iSCSI 4-port HICs |
Configuration notes:
- For preconfigured models, two 16GB DE6000 controllers (feature code BQA2) are included in the model configuration.
- For CTO models, two DE6000 controllers are required, either 16GB (feature code BQA2) or 64GB (feature code BQA1)
The models of the ThinkSystem DE6000H ship with the following items:
- One chassis with the following components:
- Two controllers
- Two power supplies
- Two cooling modules (4U60 LFF only)
- Two host interface cards
- Rack Mount Kit
- 2 m USB Cable (USB Type A to Micro-USB)
- Quick Installation Guide
- Electronic Publications Flyer
- Two power cables:
- Relationship models listed in this section:
- 2U24 SFF: 1.5 m, 10A/100-250V, C13 to IEC 320-C14 rack power cables
- 4U60 LFF: 2.5 m, 16A/100-240V, C19 to IEC 320-C20 rack power cables
- CTO models: Customer-configured power cables
- Relationship models listed in this section:
Note: The preconfigured models of the ThinkSystem DE6000H listed in this section ship without optical transceivers, DAC cables, or SAS cables; they should be purchased for the system (see Controllers for details).
Controllers
The ThinkSystem DE6000H controller enclosures ship with two DE6000 controllers, and each controller provides 16 GB or 64 GB system memory for a system total of 32 GB or 128 GB, respectively. A controller provides interfaces for host connectivity, management, and internal drives, and it runs storage management software.
Each controller has one expansion slot for a host interface card (HIC).
The following host interfaces can be added to the ThinkSystem DE6000H controller enclosures with HICs:
- 8x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) ports (4 ports per HIC) for SAS connectivity.
- 8x 10/25 GbE SFP28 ports (4 ports per HIC) for 10/25 Gb iSCSI connectivity (require optical transceivers or DAC cables that should be purchased for the HICs).
- 8x 8/16/32 Gb FC SFP+ ports (4 ports per HIC) for FC or NVMe/FC connectivity (require optical transceivers that should be purchased for the HICs).
- 4x 25/40/100 GbE RoCE QSFP28 ports (2 ports per HIC) for NVMe/RoCE connectivity (require optical transceivers or DAC cables that should be purchased for the HIC).
Each DE6000 controller also provide two 12 Gb SAS x4 expansion ports (Mini-SAS HD SFF-8644 connectors) for the attachment of the ThinkSystem DE Series expansion units.
Configuration notes:
- Both controllers must have the same system memory: 16 GB or 64 GB.
- Two host interface cards are required for selection (one per controller).
- Both controllers must have the same type of the host interface card installed (12 Gb SAS SFF-8644, 32 Gb FC SFP+, 10/25 Gb iSCSI SFP28, or 100 GbE NVMe/RoCE QSFP28), and both cards must have SFP+/SFP28/QSFP28 media of the same type (either optical transceivers or DAC cables, but not both types).
- NVMe/FC or NVMe/RoCE connectivity requires controllers with 64 GB system memory.
The following table lists the DE6000H controllers and supported connectivity options.
Part number | Feature code | Description | Maximum quantity per controller enclosure |
---|---|---|---|
Controllers | |||
None* | B4JN | Lenovo ThinkSystem DE6000 Controller 16GB | 2 |
None* | B4JP | Lenovo ThinkSystem DE6000 Controller 64GB | 2 |
Host interface cards | |||
4C57A14372 | B4J9 | Lenovo ThinkSystem DE6000 12Gb SAS 4-ports HIC | 2 |
4C57A14371 | B4J8 | Lenovo ThinkSystem DE6000 10/25Gb iSCSI 4-ports HIC | 2 |
4C57A14370 | B4J7 | Lenovo ThinkSystem DE6000 32Gb FC 4-ports HIC | 2 |
4C57A14373 | B6KW | Lenovo ThinkSystem DE6000 100Gb NVMe-RoCE 2-port HIC | 2 |
Transceiver options | |||
4M17A13527 | B4B2 | Lenovo 10Gb iSCSI/16Gb FC Universal SFP+ Module | 4 |
4M17A13529 | B4B4 | Lenovo 10/25GbE iSCSI SFP28 Module (for 10/25 Gb iSCSI HIC ports) | 8 |
4M17A13528 | B4B3 | Lenovo 32Gb FC SFP+ Transceiver (for 32 Gb FC HIC ports) | 8 |
OM4 cables for 16/32 Gb FC and 10/25 Gb iSCSI SW SFP+/SFP28 optical transceivers | |||
4Z57A10845 | B2P9 | Lenovo 0.5m LC-LC OM4 MMF Cable | 12 |
4Z57A10846 | B2PA | Lenovo 1m LC-LC OM4 MMF Cable | 12 |
4Z57A10847 | B2PB | Lenovo 3m LC-LC OM4 MMF Cable | 12 |
4Z57A10848 | B2PC | Lenovo 5m LC-LC OM4 MMF Cable | 12 |
4Z57A10849 | B2PD | Lenovo 10m LC-LC OM4 MMF Cable | 12 |
4Z57A10850 | B2PE | Lenovo 15m LC-LC OM4 MMF Cable | 12 |
4Z57A10851 | B2PF | Lenovo 25m LC-LC OM4 MMF Cable | 12 |
4Z57A10852 | B2PG | Lenovo 30m LC-LC OM4 MMF Cable | 12 |
OM3 cables for 16/32 Gb FC and 10/25 Gb iSCSI SW SFP+/SFP28 optical transceivers | |||
00MN499 | ASR5 | Lenovo 0.5m LC-LC OM3 MMF Cable | 12 |
00MN502 | ASR6 | Lenovo 1m LC-LC OM3 MMF Cable | 12 |
00MN505 | ASR7 | Lenovo 3m LC-LC OM3 MMF Cable | 12 |
00MN508 | ASR8 | Lenovo 5m LC-LC OM3 MMF Cable | 12 |
00MN511 | ASR9 | Lenovo 10m LC-LC OM3 MMF Cable | 12 |
00MN514 | ASRA | Lenovo 15m LC-LC OM3 MMF Cable | 12 |
00MN517 | ASRB | Lenovo 25m LC-LC OM3 MMF Cable | 12 |
00MN520 | ASRC | Lenovo 30m LC-LC OM3 MMF Cable | 12 |
Active optical cables for 100 Gb NVMe/RoCE QSFP28 HIC ports | |||
7Z57A03546 | AV1L | Lenovo 3m 100G QSFP28 Active Optical Cable | 4 |
7Z57A03547 | AV1M | Lenovo 5m 100G QSFP28 Active Optical Cable | 4 |
7Z57A03548 | AV1N | Lenovo 10m 100G QSFP28 Active Optical Cable | 4 |
7Z57A03549 | AV1P | Lenovo 15m 100G QSFP28 Active Optical Cable | 4 |
7Z57A03550 | AV1Q | Lenovo 20m 100G QSFP28 Active Optical Cable | 4 |
DAC cables for iSCSI HIC ports | |||
00D6288 | A3RG | 0.5m Passive DAC SFP+ Cable | 12 |
90Y9427 | A1PH | 1m Passive DAC SFP+ Cable | 12 |
00AY764 | A51N | 1.5m Passive DAC SFP+ Cable | 12 |
00AY765 | A51P | 2m Passive DAC SFP+ Cable | 12 |
90Y9430 | A1PJ | 3m Passive DAC SFP+ Cable | 12 |
90Y9433 | A1PK | 5m Passive DAC SFP+ Cable | 12 |
00D6151 | A3RH | 7m Passive DAC SFP+ Cable | 12 |
DAC cables for 25 Gb iSCSI SFP28 HIC ports | |||
7Z57A03557 | AV1W | Lenovo 1m Passive 25G SFP28 DAC Cable | 8 |
7Z57A03558 | AV1X | Lenovo 3m Passive 25G SFP28 DAC Cable | 8 |
DAC cables for 100 Gb NVMe/RoCE QSFP28 HIC ports | |||
7Z57A03561 | AV1Z | Lenovo 1m Passive 100G QSFP28 DAC Cable | 4 |
7Z57A03562 | AV20 | Lenovo 3m Passive 100G QSFP28 DAC Cable | 4 |
7Z57A03563 | AV21 | Lenovo 5m Passive 100G QSFP28 DAC Cable | 4 |
SAS host connectivity cables: Mini-SAS HD (controller) to Mini-SAS HD (host) | |||
00YL847 | AU16 | 0.5m External MiniSAS HD 8644/MiniSAS HD 8644 Cable | 8 |
00YL848 | AU17 | 1m External MiniSAS HD 8644/MiniSAS HD 8644 Cable | 8 |
00YL849 | AU18 | 2m External MiniSAS HD 8644/MiniSAS HD 8644 Cable | 8 |
00YL850 | AU19 | 3m External MiniSAS HD 8644/MiniSAS HD 8644 Cable | 8 |
1 GbE management ports | |||
00WE123 | AVFW | 0.75m Green Cat6 Cable | 2 |
00WE127 | AVFX | 1.0m Green Cat6 Cable | 2 |
00WE131 | AVFY | 1.25m Green Cat6 Cable | 2 |
00WE135 | AVFZ | 1.5m Green Cat6 Cable | 2 |
00WE139 | AVG0 | 3m Green Cat6 Cable | 2 |
90Y3718 | A1MT | 10m Green Cat6 Cable | 2 |
90Y3727 | A1MW | 25m Green Cat6 Cable | 2 |
* Factory-installed only.
Expansion enclosures
In the base configuration, the ThinkSystem DE6000H supports attachment of up to seven ThinkSystem DE240S 2U24 SFF or ThinkSystem DE120S 2U12 LFF, or up to three ThinkSystem DE600S 4U60 LFF, or a combination of the DE240S 2U24 SFF, DE120S 2U12 LFF, and DE600S 4U60 LFF expansion enclosures for a total of up to 240 drives per system.
With the optional FoD upgrade, the DH6000H supports attachment of up to seven ThinkSystem DE600S 4U60 LFF, or a combination of the DE240S 2U24 SFF, DE120S 2U12 LFF, and DE600S 4U60 LFF expansion enclosures for a total of eight enclosures (one controller enclosure and up to seven expansion enclosures) and up to 480 drives per system.
Intermix of 2U24 SFF, 2U12 LFF, and 4U60 LFF expansion enclosures behind a 2U24 SFF or 4U60 LFF controller enclosure is supported up to the maximum number of enclosures and drives supported per system (depending on whether the optional FoD upgrade is enabled or not). The expansion enclosures can be added to the system non-disruptively.
The following table lists the relationship models of the supported ThinkSystem DE Series expansion enclosures.
Description | Part number | |||||
---|---|---|---|---|---|---|
Brazil | Latin America | China | European Union | Japan | Other markets worldwide | |
Lenovo ThinkSystem DE240S 2U24 SFF Expansion Enclosure | – | – | – | 7Y68A004EA | 7Y681001JP | 7Y68A000WW |
Lenovo ThinkSystem DE120S 2U12 LFF Expansion Enclosure | – | – | – | 7Y63A003EA | 7Y631000JP | 7Y63A000WW |
Lenovo ThinkSystem DE600S 4U60 LFF Expansion Enclosure Gen2 | 7Y69A004BR | 7Y69A004LA | 7Y69A004CN | – | 7Y69A005JP | 7Y69A004WW |
The following table lists the TopSeller models of the supported ThinkSystem DE Series expansion enclosures.
Description | Part number | |
---|---|---|
Latin America | Brazil | |
Lenovo ThinkSystem DE240S 2U24 SFF Expansion Enclosure (TopSeller) | 7Y681002LA | 7Y681002BR |
Lenovo ThinkSystem DE120S 2U12 LFF Expansion Enclosure (TopSeller) | 7Y631001LA | 7Y631001BR |
The following table lists the CTO base models for the ThinkSystem DE Series expansion enclosures.
Description | Machine Type/Model | Feature code | ||
---|---|---|---|---|
European Union | Other markets | World Wide | ||
Lenovo ThinkSystem Storage 2U24 Chassis (with 2x PSUs) | 7Y68CTO1WW | BEY7 | B38L | – |
Lenovo ThinkSystem Storage 2U12 Chassis (with 2x PSUs) | 7Y63CTO1WW | BEY6 | B38M | – |
Lenovo ThinkSystem Storage 4U60 Chassis (with 2x PSUs) | 7Y69CTO2WW | – | – | BQ9W |
Configuration notes:
- For Relationship and TopSeller models, two I/O expansion modules (feature code B4BS) are included in the model configuration.
- For CTO models, two I/O expansion modules (feature code B4BS) are selected by default in the configurator, and the selection cannot be changed.
The models of the ThinkSystem DE240S, DE120S, and DE600S ship with the following items:
- One chassis with the following components:
- Two I/O modules
- Two power supplies
- Two cooling modules (4U60 LFF only)
- Four 1 m MiniSAS HD 8644/MiniSAS HD 8644 cables (Models listed in Tables 6 and 7)
- Rack Mount Kit
- Quick Installation Guide
- Electronic Publications Flyer
- Two power cables:
- Relationship and TopSeller models listed in this section:
- 2U24 SFF, 2U12 LFF: 1.5 m, 10A/100-250V, C13 to IEC 320-C14 rack power cables
- 4U60 LFF: 2.5 m, 16A/100-240V, C19 to IEC 320-C20 rack power cables
- CTO models: Customer-configured power cables
- Relationship and TopSeller models listed in this section:
Note: The Relationship and TopSeller models of the ThinkSystem DE240S, DE120S, and DE600S listed in this section ship with four 1 m SAS cables; additional SAS cables that are listed in this section can be purchased for the system, if needed.
Each ThinkSystem DE Series expansion enclosure ships with two SAS I/O expansion modules. Each I/O expansion module provides four external 12 Gb SAS x4 ports (Mini-SAS HD SFF-8644 connectors labelled Port 1-4) that are used for connections to the ThinkSystem DE6000H and for daisy chaining the expansion enclosures between each other.
Two expansion ports on the Controller A are connected to the Ports 1 and 2 on the I/O Module A in the first expansion enclosure in the chain, and the Ports 3 and 4 on the I/O Module A in the first expansion enclosure are connected to the Ports 1 and 2 on the I/O Module A in the adjacent expansion enclosure, and so on.
Two expansion ports on the Controller B are connected to the Ports 1 and 2 on the I/O Module B in the last expansion enclosure in the chain, and the Ports 3 and 4 on the I/O Module B in the expansion enclosure are connected to the Ports 1 and 2 on the I/O Module B in the adjacent expansion enclosure, and so on.
The connectivity topology for the DE Series expansion enclosures is shown in the following figure.
Figure 9. DE Series expansion enclosure connectivity topology
The following table lists ordering information for the supported expansion enclosure connectivity options.
Description | Part number | Feature code | Quantity per one expansion enclosure |
---|---|---|---|
External MiniSAS HD 8644/MiniSAS HD 8644 0.5M Cable | 00YL847 | AU16 | 4 |
External MiniSAS HD 8644/MiniSAS HD 8644 1M Cable | 00YL848 | AU17 | 4 |
External MiniSAS HD 8644/MiniSAS HD 8644 2M Cable | 00YL849 | AU18 | 4 |
External MiniSAS HD 8644/MiniSAS HD 8644 3M Cable | 00YL850 | AU19 | 4 |
Configuration notes:
- The Relationship and TopSeller models of the ThinkSystem DE240S, DE120S, and DE600S listed in this section ship with four 1 m SAS cables.
- Four SAS cables are needed per each expansion enclosure (two SAS cables per I/O Module) for connections to the controller enclosure and for daisy chaining of the expansion enclosures.
- The length of the SAS cables that connect a 2U24 or 2U12 enclosure to an adjacent 4U60 enclosure should be at least 1 meter.
Drives
The ThinkSystem DE Series 2U24 SFF enclosures support up to 24 SFF hot-swap drives, the 2U12 LFF enclosures support up to 12 LFF hot-swap drives, and the 4U60 LFF enclosures support up to 60 LFF hot-swap drives.
Shipping requirement: 2U12 and 2U24 enclosures can be shipped with all drive bays populated, however the 4U60 enclosures must be shipped with drives removed.
The following table lists supported drive options for the 2U24 SFF controller and expansion enclosures.
Part number | Feature code | DescriptionB4RX | Maximum quantity per 2U24 SFF enclosure |
---|---|---|---|
2.5-inch 12 Gbps SAS hot-swap HDDs | |||
4XB7A14112 | B4BY | Lenovo ThinkSystem DE Series 1.2TB 10K 2.5″ HDD 2U24 | 24 |
4XB7A14113 | B4BZ | Lenovo ThinkSystem DE Series 1.8TB 10K 2.5″ HDD 2U24 | 24 |
2.5-inch 12 Gbps SAS hot-swap FIPS HDDs (SED HDDs) | |||
4XB7A14114 | B4C0 | Lenovo ThinkSystem DE Series 1.8TB 10K 2.5″ HDD FIPS 2U24 | 24 |
2.5-inch 12 Gbps SAS hot-swap SSDs (1 DWPD) | |||
4XB7A74948 | BKUQ | Lenovo ThinkSystem DE Series 960GB 1DWD 2.5″ SSD 2U24 | 24 |
4XB7A74951 | BKUT | Lenovo ThinkSystem DE Series 1.92TB 1DWD 2.5″ SSD 2U24 | 24 |
4XB7A74955 | BKUK | Lenovo ThinkSystem DE Series 3.84TB 1DWD 2.5″ SSD 2U24 | 24 |
4XB7A14176 | B4RY | Lenovo ThinkSystem DE Series 7.68TB 1DWD 2.5″ SSD 2U24 | 24 |
4XB7A14110 | B4CD | Lenovo ThinkSystem DE Series 15.36TB 1DWD 2.5″ SSD 2U24 | 24 |
2.5-inch 12 Gbps SAS hot-swap SSDs (3 DWPD) | |||
4XB7A14105 | B4BT | Lenovo ThinkSystem DE Series 800GB 3DWD 2.5″ SSD 2U24 | 24 |
2.5-inch 12 Gbps SAS hot-swap FIPS SSDs (SED SSDs) (3 DWPD) | |||
4XB7A14107 | B4BV | Lenovo ThinkSystem DE Series 1.6TB 3DWD 2.5″ SSD FIPS 2U24 | 24 |
The following table lists supported drive options for the 2U12 LFF expansion enclosures for the DE6000H.
Part number | Feature code | Description | Maximum quantity per 2U12 LFF enclosure |
---|---|---|---|
3.5-inch 12 Gbps NL SAS hot-swap HDDs | |||
4XB7A14099 | B4C3 | Lenovo ThinkSystem DE Series 4TB 7.2K 3.5″ HDD 2U12 | 12 |
4XB7A14101 | B4C5 | Lenovo ThinkSystem DE Series 8TB 7.2K 3.5″ HDD 2U12 | 12 |
4XB7A14102 | B4C6 | Lenovo ThinkSystem DE Series 10TB 7.2K 3.5″ HDD 2U12 | 12 |
4XB7A14104 | B4C8 | Lenovo ThinkSystem DE Series 12TB 7.2K 3.5″ HDD 2U12 | 12 |
4XB7A64875 | BCVY | Lenovo ThinkSystem DE Series 16TB 7.2K 3.5″ HDD 2U12 | 12 |
4XB7A74942 | BHDP | Lenovo ThinkSystem DE Series 18TB 7.2K 3.5″ HDD 2U12 | 12 |
3.5-inch 12 Gbps NL SAS hot-swap FIPS HDDs (SED HDDs) | |||
4XB7A14103 | B4C7 | Lenovo ThinkSystem DE Series 10TB 7.2K 3.5″ HDD FIPS 2U12 | 12 |
3.5-inch 12 Gbps SAS hot-swap SSDs (3 DWPD) | |||
4XB7A14097 | B4C1 | Lenovo ThinkSystem DE Series 800GB 3DWD 2.5″ SSD 2U12 | 12 |
3.5-inch 12 Gbps SAS hot-swap FIPS SSDs (SED SSDs) (3 DWPD) (2.5″ drive in a 3.5″ tray) | |||
4XB7A14098 | B4C2 | Lenovo ThinkSystem DE Series 1.6TB 3DWD 2.5″ SSD FIPS 2U12 | 12 |
The following table lists supported drive options for the 4U60 LFF controller and expansion enclosures.
Part number | Feature code | Description | Maximum quantity per 4U60 LFF enclosure |
---|---|---|---|
3.5-inch 12 Gbps NL SAS hot-swap HDDs | |||
4XB7A14124 | B4GG | Lenovo ThinkSystem DE Series 4TB 7.2K 3.5″ HDD 4U60 | 60 |
4XB7A14125 | B4GH | Lenovo ThinkSystem DE Series 8TB 7.2K 3.5″ HDD 4U60 | 60 |
4XB7A14126 | B4GJ | Lenovo ThinkSystem DE Series 10TB 7.2K 3.5″ HDD 4U60 | 60 |
4XB7A14128 | B4GL | Lenovo ThinkSystem DE Series 12TB 7.2K 3.5″ HDD 4U60 | 60 |
4XB7A64876 | BCUC | Lenovo ThinkSystem DE Series 16TB 7.2K 3.5″ HDD 4U60 | 60 |
4XB7A74943 | BHDQ | Lenovo ThinkSystem DE Series 18TB 7.2K 3.5″ HDD 4U60 | 60 |
3.5-inch 12 Gbps NL SAS hot-swap FIPS HDDs (SED HDDs) | |||
4XB7A14127 | B4GK | Lenovo ThinkSystem DE Series 10TB 7.2K 3.5″ HDD FIPS 4U60 | 60 |
3.5-inch 12 Gbps SAS hot-swap SSDs (1 DWPD) (2.5″ drive in a 3.5″ tray) | |||
4XB7A86719 | BUC8 | Lenovo ThinkSystem DE Series 1.92TB 1DWD SAS SSD 4U60 | 60 |
3.5-inch 12 Gbps SAS hot-swap SSDs (3 DWPD) (2.5″ drive in a 3.5″ tray) | |||
4XB7A14115 | B4G9 | Lenovo ThinkSystem DE Series 800GB 3DWD 2.5″ SSD 4U60 | 60 |
4XB7A14116 | B4GA | Lenovo ThinkSystem DE Series 1.6TB 3DWD 2.5″ SSD 4U60 | 60 |
3.5-inch 12 Gbps SAS hot-swap FIPS SSDs (SED SSDs) (3 DWPD) (2.5″ drive in a 3.5″ tray) | |||
4XB7A14117 | B4GB | Lenovo ThinkSystem DE Series 1.6TB 3DWD 2.5″ SSD FIPS 4U60 | 60 |
The following table lists supported drive pack options for the 4U60 LFF controller and expansion enclosures.
Part number | Feature code | Description | Maximum quantity per 4U60 LFF enclosure |
---|---|---|---|
3.5-inch 12 Gbps NL SAS hot-swap HDD packs | |||
4XB7A14164 | B4HY | Lenovo ThinkSystem DE6000H 80TB HDD Pack (20x 4TB HDDs) | 3 |
4XB7A14166 | B4HZ | Lenovo ThinkSystem DE6000H 160TB HDD Pack (20x 8TB HDDs) | 3 |
4XB7A14168 | B4J0 | Lenovo ThinkSystem DE6000H 200TB HDD Pack (20x 10TB HDDs) | 3 |
4XB7A14172 | B4J2 | Lenovo ThinkSystem DE6000H 240TB HDD Pack (20x 12TB HDDs) | 3 |
4XB7A64878 | BCUE | Lenovo ThinkSystem DE6000H 320TB HDD Pack (20x 16TB HDDs) | 3 |
4XB7A74945 | BHDS | Lenovo ThinkSystem DE6000H 360TB HDD Pack (20x 18TB HDDs) | 3 |
3.5-inch 12 Gbps NL SAS hot-swap FIPS HDD packs (SED HDD packs) | |||
4XB7A14170 | B4J1 | Lenovo ThinkSystem DE6000H 200TB HDD FIPS Pack (20x 10TB FIPS HDDs) | 3 |
3.5-inch 12 Gbps SAS hot-swap SSD packs (1 DWPD) (2.5″ drive in a 3.5″ tray) | |||
4XB7A86720* | BUC9 | Lenovo ThinkSystem DE4000H 38.4TB Pack (20x 1.92TB SAS SSDs) | 3 |
4XB7A86721 | BUCA | Lenovo ThinkSystem DE6000H 38.4TB Pack (20x 1.92TB SAS SSDs) | 3 |
3.5-inch 12 Gbps SAS hot-swap SSD packs (3 DWPD) (2.5″ drive in a 3.5″ tray) | |||
4XB7A14162 | B4HX | Lenovo ThinkSystem DE6000H 32TB SSD Pack (20x 1.6TB SSDs) | 3 |
*Supported in the DE600S 4U60 LFF Expansion Enclosure (7Y69) only.
Configuration notes:
- For hybrid (HDDs and SSDs) and all flash (SSDs only) storage configurations, a single ThinkSystem DE6000H storage system can support a maximum of 120 SSDs.
- A minimum of 20 drives is required for each 4U60 LFF enclosure (the front row of each drawer must be populated with four drives).
- Intermix of FIPS drives and non-FIPS drives is supported within the system.
- FIPS drives are not available in the following countries:
- Belarus
- Kazakhstan
- People’s Republic of China
- Russia
Software
The following functions are included with every ThinkSystem DE6000H:
- RAID levels 0, 1, 3, 5, 6, and 10: Provide the flexibility to choose the level of performance and data protection required.
- Dynamic Disk Pools (DDP) technology: Helps improve performance and availability with significantly faster rebuild time and reduced exposure to multiple drive failures by allowing data and built-in spare capacity to be distributed across all physical drives in the storage pool.
- All Flash Array (AFA) capability: Meets the demand for higher speed storage and provide higher IOPS and bandwidth with lower power usage and total cost of ownership than hybrid or HDD-based solutions.
- SSD Read Cache: Helps accelerate performance of read-centric workloads.
- Thin provisioning: Optimizes efficiency of Dynamic Disk Pools by allocating storage space based on the minimum space required by each application at any given time, so that applications consume only the space they are actually using, not the total space that has been allocated to them, which allows customers to purchase storage they need today and add more as application requirements grow.
- Snapshots: Enables creation of copies of data for backup, parallel processing, testing, and development, and have the copies available almost immediately (up to 1024 snapshot targets per system).
- Encryption: Provides encryption for data at rest for enhanced data security with the optional FIPS 140-2 Level 2 drives and embedded key management (AES-256) or an external key management server.
- Automatic load balancing: Provides automated I/O workload balancing of I/O traffic from the hosts across both controllers.
- Data assurance: Ensures industry-standard T10-PI end-to-end data integrity in the storage system (from the host ports to the drives).
- Dynamic volume and capacity expansion: Allows the capacity of a volume to be expanded by adding new physical drives or making use of unused space on existing drives.
The ThinkSystem DE6000H capabilities can be expanded with optional licensed functions. Optional licensed functions include:
- Snapshots upgrade: Increase the supported number of snapshot targets to 2048.
- Scalability to 480 drives: Increases the number of supported 4U60 LFF expansion enclosures to 7 for up to 480 LFF drives per system.
- Synchronous mirroring: Provides storage system-based online, real-time data replication between the storage systems containing primary (local) and secondary (remote) volumes by using synchronous data transfers over Fibre Channel communication links (both storage systems must have licenses for synchronous mirroring).
- Asynchronous mirroring: Provides storage system-based data replication between the storage systems containing primary (local) and secondary (remote) volumes by using asynchronous data transfers over iSCSI or Fibre Channel communication links at set intervals (both storage systems must have licenses for asynchronous mirroring).
Note: The synchronous and asynchronous mirroring features of the ThinkSystem DE6000H interoperate with other ThinkSystem DE Series storage arrays.
The following table lists the Feature on Demand (FoD) upgrades for the ThinkSystem DE6000H to enable optional software features. Each optional DE6000H function is licensed on a per-system basis and covers both controller enclosure and all attached expansion enclosures.
Description | Part number | Feature code |
---|---|---|
Lenovo ThinkSystem DE6000H Snapshots Upgrade 2048 | 4ZN7A14704 | B4JA |
Lenovo ThinkSystem DE6000H Max Drive Count Increase to 480 | 4ZN7A14710 | B597 |
Lenovo ThinkSystem DE6000H Synchronous Mirroring | 4ZN7A14706 | B4JB |
Lenovo ThinkSystem DE6000H Asynchronous Mirroring | 4ZN7A14707 | B4JC |
Software maintenance is included in the ThinkSystem DE6000H base warranty and optional warranty extensions, which provides 3-year software support with the option to extend it up to 5 years in 1-year or 2-year increments (see Warranty and support for details).
Management
The DE6000H supports the following management interfaces:
- ThinkSystem System Manager, a web-based interface via HTTPS for single-system management, that runs on the storage system itself and requires only a supported browser, so there is no need for a separate console or plug-in. For more information, see the System Manager Online Help.
- ThinkSystem SAN Manager, a host-installed GUI-based application, for centralized management of multiple storage systems. For more information, see the SAN Manager Online Help.
- ThinkSystem DE Series Storage Plugin for vCenter. For more information, see the DE Series vCenter Plugin Online Help.
- Command line interface (CLI) via SSH or through serial console. For more information, see the CLI Online Help.
- Syslog, SNMP, and e-mail notifications.
- Optional Lenovo XClarity Administrator support for discovery, inventory, and monitoring.
Power supplies and cables
The ThinkSystem DE Series 2U24 SFF and 2U12 LFF enclosures ship with two redundant hot-swap 913W (100-240V) Platinum AC power supplies, each with an IEC 320-C14 connector. The Relationship models of the ThinkSystem DE6000H 2U24 SFF, DE240S 2U24 SFF, and DE120S 2U12 LFF enclosures listed in Controller enclosures and Expansion enclosures ship with two 1.5 m, 10A/100-250V, C13 to IEC 320-C14 rack power cables.
The ThinkSystem DE Series 4U60 LFF enclosures ship with two redundant hot-swap 2325 W (200 – 240 V) Platinum AC power supplies, each with an IEC 320-C20 connector. The Relationship models of the ThinkSystem DE6000H 4U60 LFF and DE600S 4U60 LFF enclosures listed in Controller enclosures and Expansion enclosures ship with two 2.5 m, 16A/100-240V, C19 to IEC 320-C20 rack power cables.
The CTO models require the selection of two power cables.
The following table lists the rack power cable and line cord options that can be ordered for the DE Series 2U24 SFF enclosures (two power cords per enclosure).
Description | Part number | Feature code |
---|---|---|
Rack power cables | ||
1.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 00Y3043 | A4VP |
1.0m, 13A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08367 | B0N5 |
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7937 | 6201 |
1.5m, 13A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08368 | B0N6 |
2.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08365 | B0N4 |
2.0m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08369 | 6570 |
2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08366 | 6311 |
2.8m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08370 | 6400 |
2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable | 39Y7938 | 6204 |
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7932 | 6263 |
4.3m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08371 | 6583 |
Line cords | ||
Argentina 2.8m, 10A/250V, C13 to IRAM 2073 Line Cord | 39Y7930 | 6222 |
Argentina 4.3m, 10A/250V, C13 to IRAM 2073 Line Cord | 81Y2384 | 6492 |
Australia/New Zealand 2.8m, 10A/250V, C13 to AS/NZS 3112 Line Cord | 39Y7924 | 6211 |
Australia/New Zealand 4.3m, 10A/250V, C13 to AS/NZS 3112 Line Cord | 81Y2383 | 6574 |
Brazil 2.8m, 10A/250V, C13 to NBR 14136 Line Cord | 69Y1988 | 6532 |
Brazil 4.3m, 10A/250V, C13 to NBR14136 Line Cord | 81Y2387 | 6404 |
China 2.8m, 10A/250V, C13 to GB 2099.1 Line Cord | 39Y7928 | 6210 |
China 4.3m, 10A/250V, C13 to GB 2099.1 Line Cord | 81Y2378 | 6580 |
Denmark 2.8m, 10A/250V, C13 to DK2-5a Line Cord | 39Y7918 | 6213 |
Denmark 4.3m, 10A/250V, C13 to DK2-5a Line Cord | 81Y2382 | 6575 |
Europe 2.8m, 10A/250V, C13 to CEE7-VII Line Cord | 39Y7917 | 6212 |
Europe 4.3m, 10A/250V, C13 to CEE7-VII Line Cord | 81Y2376 | 6572 |
India 2.8m, 10A/250V, C13 to IS 6538 Line Cord | 39Y7927 | 6269 |
India 4.3m, 10A/250V, C13 to IS 6538 Line Cord | 81Y2386 | 6567 |
Israel 2.8m, 10A/250V, C13 to SI 32 Line Cord | 39Y7920 | 6218 |
Israel 4.3m, 10A/250V, C13 to SI 32 Line Cord | 81Y2381 | 6579 |
Italy 2.8m, 10A/250V, C13 to CEI 23-16 Line Cord | 39Y7921 | 6217 |
Italy 4.3m, 10A/250V, C13 to CEI 23-16 Line Cord | 81Y2380 | 6493 |
Japan 2.8m, 12A/125V, C13 to JIS C-8303 Line cord | 46M2593 | A1RE |
Japan 2.8m, 12A/250V, C13 to JIS C-8303 Line Cord | 4L67A08357 | 6533 |
Japan 4.3m, 12A/125V, C13 to JIS C-8303 Line Cord | 39Y7926 | 6335 |
Japan 4.3m, 12A/250V, C13 to JIS C-8303 Line Cord | 4L67A08362 | 6495 |
Korea 2.8m, 12A/250V, C13 to KS C8305 Line Cord | 39Y7925 | 6219 |
Korea 4.3m, 12A/250V, C13 to KS C8305 Line Cord | 81Y2385 | 6494 |
South Africa 2.8m, 10A/250V, C13 to SABS 164 Line Cord | 39Y7922 | 6214 |
South Africa 4.3m, 10A/250V, C13 to SABS 164 Line Cord | 81Y2379 | 6576 |
Switzerland 2.8m, 10A/250V, C13 to SEV 1011-S24507 Line Cord | 39Y7919 | 6216 |
Switzerland 4.3m, 10A/250V, C13 to SEV 1011-S24507 Line Cord | 81Y2390 | 6578 |
Taiwan 2.8m, 10A/125V, C13 to CNS 10917-3 Line Cord | 23R7158 | 6386 |
Taiwan 2.8m, 10A/250V, C13 to CNS 10917-3 Line Cord | 81Y2375 | 6317 |
Taiwan 2.8m, 15A/125V, C13 to CNS 10917-3 Line Cord | 81Y2374 | 6402 |
Taiwan 4.3m, 10A/125V, C13 to CNS 10917-3 Line Cord | 4L67A08363 | AX8B |
Taiwan 4.3m, 10A/250V, C13 to CNS 10917-3 Line Cord | 81Y2389 | 6531 |
Taiwan 4.3m, 15A/125V, C13 to CNS 10917-3 Line Cord | 81Y2388 | 6530 |
United Kingdom 2.8m, 10A/250V, C13 to BS 1363/A Line Cord | 39Y7923 | 6215 |
United Kingdom 4.3m, 10A/250V, C13 to BS 1363/A Line Cord | 81Y2377 | 6577 |
United States 2.8m, 10A/125V, C13 to NEMA 5-15P Line Cord | 90Y3016 | 6313 |
United States 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord | 46M2592 | A1RF |
United States 2.8m, 13A/125V, C13 to NEMA 5-15P Line Cord | 00WH545 | 6401 |
United States 4.3m, 10A/125V, C13 to NEMA 5-15P Line Cord | 4L67A08359 | 6370 |
United States 4.3m, 10A/250V, C13 to NEMA 6-15P Line Cord | 4L67A08361 | 6373 |
United States 4.3m, 13A/125V, C13 to NEMA 5-15P Line Cord | 4L67A08360 | AX8A |
The following table lists the rack power cable and line cord options that can be ordered for the DE Series 4U60 LFF enclosures (two power cords per enclosure).
Description | Part number | Feature code |
---|---|---|
Rack power cables | ||
2.0m, 16A/100-250V, C19 to IEC 320-C20 Rack Power Cable | None* | B4L2 |
2.5m, 16A/100-250V, C19 to IEC 320-C20 Rack Power Cable | 39Y7916 | 6252 |
Line cords | ||
Argentina 4.3m, 16A/250V, C19 to IRAM 2073 Line Cord | 40K9777 | 6276 |
Australia/New Zealand 4.3m, 15A/250V, C19 to AS/NZS 3112 Line Cord | 40K9773 | 6284 |
Brazil 4.3m, 16A/250V, C19 to NBR 14136 Line Cord | 40K9775 | 6277 |
China 4.3m, 16A/250V, C19 to GB2099.1 Line Cord | 40K9774 | 6288 |
Denmark/Switzerland 4.3m, 16A/250V, C19 to IEC 309 P+N+G Line Cord | 40K9769 | 6283 |
Europe 4.3m, 16A/250V, C19 to CEE7-VII Line Cord | 40K9766 | 6279 |
India 4.3m, 16A/250V, C19 to IS6538 Line Cord | 40K9776 | 6285 |
Israel 4.3m, 16A/250V, C19 to SI 32 Line Cord | 40K9771 | 6282 |
Italy 4.3m, 16A/250V, C19 to CEI 23-16 Line Cord | 40K9768 | 6281 |
Japan 4.3m, 15A/200V, C19 to JIS C-8303 Line Cord | 41Y9233 | 6291 |
Korea 4.3m, 15A/250V, C19 to KSC 8305 Line Cord | 41Y9231 | 6289 |
South Africa 4.3m, 16A/250V, C19 to SABS 164 Line Cord | 40K9770 | 6280 |
Switzerland 4.3m, 16A/250V, C19 to SEV 1011 Line Cord | 81Y2391 | 6549 |
Taiwan 4.3m, 16A/250V, C19 to CNS 10917-3 Line Cord | 41Y9230 | 6287 |
United Kingdom 4.3m, 13A/250V, C19 to BS 1363/A Line Cord | 40K9767 | 6278 |
United States 4.3m, 15A/250V, C19 to NEMA 6-15P Line Cord | 00D7197 | A1NV |
United States 4.3m, 18A/250V, C19 to NEMA L6-20P Line Cord | 40K9772 | 6275 |
* CTO only.
Rack installation
The individually shipped ThinkSystem DE Series 2U12 enclosures come with the ThinkSystem Storage Rack Mount Kit 2U12, and the individually shipped ThinkSystem DE Series 2U24 and 4U60 enclosures come with the ThinkSystem Storage Rack Mount Kit 2U24/4U60. These rack mount kits are listed in the following table.
Description | Feature code | Quantity |
---|---|---|
Lenovo ThinkSystem Storage Rack Mount Kit 2U12 | B38X | 1 |
Lenovo ThinkSystem Storage Rack Mount Kit 2U24/4U60 | B38Y | 1 |
When the ThinkSystem DE Series enclosures are factory-integrated and shipped installed in a rack cabinet, the rack mount kits that support Ship-in-Rack (SIR) capabilities are derived by the configurator. The SIR-capable rack mount kits are listed in the following table.
Description | Feature code | Quantity |
---|---|---|
Lenovo ThinkSystem Storage Rack Mount Kit 2U12 | B38X | 1 |
Lenovo ThinkSystem Storage SIR Rack Mount Kit (for 2U24 enclosures) | B6TH | 1 |
DM/DE 4U Adjustable Rail Kit (SIR) | B742 | 1 |
The following table summarizes the rack mount kit features and specifications.
Attribute | Screw-in fixed rail with adjustable depth | |||
---|---|---|---|---|
2U12 | 2U24/4U60 | 2U24 SIR | 4U SIR | |
Feature code | B38X | B38Y | B6TH | B742 |
Enclosure support | DE120S | DE6000H 2U DE6000H 4U‡ DE240S DE600S‡ |
DE6000H 2U DE240S |
DE6000H 4U‡ DE600S‡ |
Rail type | Fixed (static) with adjustable depth | Fixed (static) with adjustable depth | Fixed (static) with adjustable depth | Fixed (static) with adjustable depth |
Tool-less installation | No | No | No | No |
In-rack maintenance | Yes* | Yes* | Yes* | Yes* |
Ship-in-rack (SIR) support | Yes | No | Yes | Yes |
1U PDU support | Yes | Yes | Yes | Yes |
0U PDU support | Limited** | Limited** | Limited** | Limited** |
Rack type | IBM or Lenovo 4-post, IEC standard-compliant | IBM or Lenovo 4-post, IEC standard-compliant | IBM or Lenovo 4-post, IEC standard-compliant | IBM or Lenovo 4-post, IEC standard-compliant |
Mounting holes | Square or round | Square or round | Square or round | Square or round |
Mounting flange thickness | 2 mm (0.08 in.) – 3.3 mm (0.13 in.) |
2 mm (0.08 in.) – 3.3 mm (0.13 in.) |
2 mm (0.08 in.) – 3.3 mm (0.13 in.) |
2 mm (0.08 in.) – 3.3 mm (0.13 in.) |
Distance between front and rear mounting flanges^ | 605 mm (23.8 in.) – 812.8 mm (32 in.) |
605 mm (23.8 in.) – 812.8 mm (32 in.) |
605 mm (23.8 in.) – 812.8 mm (32 in.) |
605 mm (23.8 in.) – 812.8 mm (32 in.) |
‡ The rack cabinet must be at least 1100 mm (43.31 in.) deep for 4U60 enclosures.
* The majority of the enclosure components can be serviced from the front or rear of the enclosure, which does not require the removal of the enclosure from the rack cabinet.
** If a 0U PDU is used, the rack cabinet must be at least 1000 mm (39.37 in.) deep for 2U12 and 2U24 enclosures, or at least 1200 mm (47.24 in.) deep for 4U60 enclosures.
^ Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail.
Physical specifications
The ThinkSystem DE Series 2U24 SFF enclosures have the following dimensions:
- Height: 85 mm (3.4 in.)
- Width: 449 mm (17.7 in.)
- Depth: 553 mm (21.8 in.)
The ThinkSystem DE Series 2U12 LFF enclosures have the following dimensions:
- Height: 85 mm (3.4 in.)
- Width: 447 mm (17.6 in.)
- Depth: 483 mm (19.0 in.)
The ThinkSystem DE Series 4U60 LFF enclosures have the following dimensions:
- Height: 174 mm (6.9 in.)
- Width: 449 mm (17.7 in.)
- Depth: 922 mm (36.3 in.)
Weights of enclosures (fully configured):
- DE6000H 2U24 SFF controller enclosure (7Y78): 25.07 kg (55.3 lb)
- DE6000H 4U60 LFF controller enclosure (7Y80): 108.49 kg (239.2 lb)
- DE240S 2U24 SFF expansion enclosure (7Y68): 27.44 kg (60.5 lb)
- DE120S 2U12 LFF expansion enclosure (7Y63): 27.12 kg (59.8 lb)
- DE600S 4U60 LFF expansion enclosure (7Y69): 112.2 kg (247.4 lb)
Operating environment
The ThinkSystem DE Series 2U24 SFF and 4U60 LFF enclosures are supported in the following environment:
- Air temperature:
- Operating:
- DE6000H and DE240S 2U24 SFF: 5 °C – 45 °C (41 °F – 113 °F)
- DE6000H and DE600S 4U60 LFF: 10 °C – 40 °C (50 °F – 104 °F)
- DE120S 2U12 LFF: 10 °C – 40 °C (50 °F – 104 °F)
- Non-operating: -10 °C – +50 °C (14 °F – 122 °F)
- Maximum altitude: 3050 m (10,000 ft)
- Operating:
- Relative humidity:
- Operating: 8% – 90% (non-condensing)
- Non-operating: 10% – 90% (non-condensing)
- Electrical power:
- 100 to 127 V AC (nominal); 50 Hz / 60 Hz (except 4U60 LFF enclosures)
- 200 to 240 V AC (nominal); 50 Hz / 60 Hz
- Acoustical noise emission:
- DE6000H 2U24 SFF, DE6000H and DE600S 4U60 SFF: 7.2 bels
- DE240S 2U24 SFF and DE120S 2U12 LFF: 6.6 bels
The following table lists the maximum enclosure power load, inlet current, and heat output based on the source voltage.
Enclosure | Source voltage (nominal) |
Maximum power load |
Current per inlet |
Heat output |
---|---|---|---|---|
DE6000H 2U24 SFF | 100 – 127 V AC | 814 W | 8.57 A | 2778 BTU/hour |
200 – 240 V AC | 705 W | 3.72 A | 2406 BTU/hour | |
DE6000H 4U60 LFF | 200 – 240 V AC | 1638 W | 8.63 A | 5589 BTU/hour |
DE240S 2U24 SFF | 100 – 127 V AC | 389 W | 4.1 A | 1328 BTU/hour |
200 – 240 V AC | 382 W | 2.02 A | 1304 BTU/hour | |
DE120S 2U12 LFF | 100 – 127 V AC | 306 W | 3.3 A | 1045 BTU/hour |
200 – 240 V AC | 300 W | 1.58 A | 1024 BTU/hour | |
DE600S 4U60 LFF | 200 – 240 V AC | 1446 W | 7.62 A | 4934 BTU/hour |